CVE-2021-22277

7.5 HIGH

📋 TL;DR

This CVE describes an improper input validation vulnerability in multiple ABB industrial control system products. An attacker can send specially crafted input to cause denial of service, potentially disrupting industrial operations. Organizations using ABB 800xA, AC 800M, Control Builder Safe, Compact Product Suite, or SoftControl are affected.

💻 Affected Systems

Products:
  • ABB 800xA
  • Control Software for AC 800M
  • Control Builder Safe
  • Compact Product Suite - Control and I/O
  • ABB Base Software for SoftControl
Versions: Multiple versions - see vendor advisory for specific affected versions
Operating Systems: Windows-based industrial control systems
Default Config Vulnerable: ⚠️ Yes
Notes: Systems must be running affected ABB software versions. The vulnerability affects the control software layer rather than specific operating system versions.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete disruption of industrial control systems leading to production shutdown, safety system impairment, or process instability in critical infrastructure.

🟠

Likely Case

Temporary denial of service affecting specific controllers or workstations, requiring manual restart and causing production delays.

🟢

If Mitigated

Limited impact to non-critical systems with proper network segmentation and monitoring in place.

🌐 Internet-Facing: MEDIUM - While industrial control systems shouldn't be internet-facing, misconfigurations or remote access solutions could expose them.
🏢 Internal Only: HIGH - These systems are typically deployed in internal industrial networks where attackers could gain access through other means.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

The vulnerability involves improper input validation, which typically requires sending malformed data to vulnerable endpoints. No public exploit code has been identified.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: See vendor advisory for specific patched versions

Vendor Advisory: https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499&LanguageCode=en&DocumentPartId=&Action=Launch

Restart Required: Yes

Instructions:

1. Review ABB advisory 7PAA001499. 2. Identify affected systems and versions. 3. Apply vendor-provided patches. 4. Restart affected systems. 5. Test functionality post-patch.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate ABB control systems from untrusted networks using firewalls and network segmentation

Input Validation Rules

all

Implement network-level input validation using industrial firewalls or intrusion prevention systems

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate ABB systems from potential attack vectors
  • Deploy industrial intrusion detection systems to monitor for exploitation attempts

🔍 How to Verify

Check if Vulnerable:

Check system version against ABB advisory 7PAA001499. Review system logs for unexpected input validation errors.

Check Version:

Check ABB software version through Control Builder or system management interface (vendor-specific commands vary)

Verify Fix Applied:

Verify patch installation through version check and test system functionality. Monitor for continued stability.

📡 Detection & Monitoring

Log Indicators:

  • Unexpected input validation errors
  • System crashes or restarts
  • Connection attempts to control system ports

Network Indicators:

  • Unusual traffic patterns to ABB control system ports
  • Malformed packets targeting industrial protocols

SIEM Query:

source="ABB_Control_System" AND (event_type="crash" OR event_type="validation_error")

🔗 References

📤 Share & Export