CVE-2020-9306

8.8 HIGH

📋 TL;DR

This vulnerability allows attackers to gain unauthorized access to Tesla SolarCity Solar Monitoring Gateway devices through hard-coded credentials stored in plaintext. Affected systems include Digi ConnectPort X2e devices running vulnerable firmware versions, potentially exposing solar monitoring infrastructure to compromise.

💻 Affected Systems

Products:
  • Tesla SolarCity Solar Monitoring Gateway
  • Digi ConnectPort X2e
Versions: through 5.46.43
Operating Systems: Embedded Linux
Default Config Vulnerable: ⚠️ Yes
Notes: Devices using Digi ConnectPort X2e hardware with vulnerable firmware versions are affected. The hard-coded credentials are stored in a .pyc file.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete device takeover allowing attackers to manipulate solar monitoring data, disrupt energy monitoring, pivot to internal networks, or use devices as footholds for further attacks.

🟠

Likely Case

Unauthorized access to monitoring systems allowing data theft, configuration changes, or service disruption of solar monitoring capabilities.

🟢

If Mitigated

Limited impact if devices are properly segmented and access controls prevent credential use from being leveraged for further access.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ⚠️ Yes
Weaponized: CONFIRMED
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

FireEye has published detailed exploitation techniques. Attackers can extract credentials from the .pyc file and gain access without authentication.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Versions after 5.46.43

Vendor Advisory: https://www.fireeye.com/blog/threat-research.html

Restart Required: Yes

Instructions:

1. Check current firmware version. 2. Contact Tesla/SolarCity support for firmware update. 3. Apply firmware update to version newer than 5.46.43. 4. Restart device after update.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate Solar Monitoring Gateway devices from internet and restrict internal network access

Credential Rotation

linux

Change python user password if device allows credential modification

passwd python

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate affected devices
  • Monitor for unauthorized access attempts and credential usage

🔍 How to Verify

Check if Vulnerable:

Check firmware version via device web interface or SSH if accessible. Versions 5.46.43 and earlier are vulnerable.

Check Version:

ssh python@device_ip 'cat /etc/version' or check web interface

Verify Fix Applied:

Confirm firmware version is newer than 5.46.43 and attempt to authenticate with hard-coded credentials should fail.

📡 Detection & Monitoring

Log Indicators:

  • Failed authentication attempts for python user
  • Successful logins from unexpected IPs
  • Unauthorized configuration changes

Network Indicators:

  • SSH connections to port 22 from unexpected sources
  • Unusual outbound traffic from monitoring devices

SIEM Query:

source="solar_gateway" AND (event="authentication" AND user="python") OR (event="configuration_change")

🔗 References

📤 Share & Export