CVE-2020-9120

7.5 HIGH

📋 TL;DR

A resource management error vulnerability in Huawei CloudEngine 1800V allows remote attackers to send specific messages that disrupt normal message forwarding. This affects CloudEngine 1800V devices running vulnerable software versions. Attackers could potentially cause denial of service or other impacts.

💻 Affected Systems

Products:
  • Huawei CloudEngine 1800V
Versions: V100R019C10SPC500
Operating Systems: Huawei VRP (Versatile Routing Platform)
Default Config Vulnerable: ⚠️ Yes
Notes: Only affects CloudEngine 1800V virtual switch devices running the specific vulnerable version.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete disruption of network traffic forwarding, causing denial of service for connected systems and potential cascading network failures.

🟠

Likely Case

Degraded network performance, intermittent packet loss, and potential service disruption for applications relying on the affected device.

🟢

If Mitigated

Limited impact with proper network segmentation and monitoring, potentially only affecting isolated network segments.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: MEDIUM

Exploitation requires sending specific message types to the device, but exact details are not publicly documented.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: V100R019C10SPC600 or later

Vendor Advisory: https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20201202-01-cloudengine-en

Restart Required: Yes

Instructions:

1. Download the patched firmware version V100R019C10SPC600 or later from Huawei support portal. 2. Backup current configuration. 3. Upload and install the new firmware. 4. Reboot the device. 5. Verify the new version is running.

🔧 Temporary Workarounds

Network Access Control

all

Restrict network access to CloudEngine 1800V management interfaces to trusted sources only.

Configure ACLs to limit access to device management interfaces

Traffic Filtering

all

Implement network filtering to block suspicious message types targeting the device.

Configure firewall rules to filter traffic to CloudEngine 1800V

🧯 If You Can't Patch

  • Isolate the CloudEngine 1800V device in a separate network segment with strict access controls.
  • Implement network monitoring and intrusion detection to alert on suspicious traffic patterns targeting the device.

🔍 How to Verify

Check if Vulnerable:

Check the device firmware version via CLI: display version

Check Version:

display version

Verify Fix Applied:

After patching, verify the version shows V100R019C10SPC600 or later and test message forwarding functionality.

📡 Detection & Monitoring

Log Indicators:

  • Unusual message processing errors
  • Resource exhaustion warnings
  • Forwarding plane disruptions

Network Indicators:

  • Abnormal traffic patterns to CloudEngine 1800V
  • Sudden drops in forwarded traffic
  • Increased error rates

SIEM Query:

source="CloudEngine" AND (message_processing_error OR forwarding_disruption)

🔗 References

📤 Share & Export