CVE-2020-8714

7.8 HIGH

📋 TL;DR

This vulnerability allows an authenticated user with local access to Intel server hardware to potentially escalate privileges due to improper authentication in the firmware. It affects Intel Server Boards, Server Systems, and Compute Modules running firmware versions before 1.59.

💻 Affected Systems

Products:
  • Intel Server Boards
  • Intel Server Systems
  • Intel Compute Modules
Versions: All versions before 1.59
Operating Systems: Any OS running on affected hardware
Default Config Vulnerable: ⚠️ Yes
Notes: Requires local access to the server hardware management interface (BMC/iDRAC/ILO equivalent).

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

An authenticated attacker gains administrative control over the server hardware, potentially compromising the entire system and any hosted services.

🟠

Likely Case

An insider or compromised account with local access escalates privileges to perform unauthorized firmware modifications or access restricted hardware functions.

🟢

If Mitigated

With strict access controls and monitoring, impact is limited to authorized personnel only, reducing escalation opportunities.

🌐 Internet-Facing: LOW - Requires local physical or network access to the server hardware management interface.
🏢 Internal Only: HIGH - Exploitable by any authenticated user with local access to vulnerable Intel server hardware.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: MEDIUM

Requires authenticated access to the server hardware management interface; exploitation details not publicly documented.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Version 1.59 or later

Vendor Advisory: https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00384.html

Restart Required: Yes

Instructions:

1. Download firmware update 1.59 or later from Intel support site. 2. Apply firmware update through server management interface. 3. Reboot the server to complete installation.

🔧 Temporary Workarounds

Restrict Management Interface Access

all

Limit network access to server management interfaces to authorized administrative networks only.

Configure firewall rules to restrict access to BMC/IPMI management ports (default 623/664)

Enforce Strong Authentication

all

Implement multi-factor authentication and strong password policies for server management interfaces.

Configure BMC/IPMI authentication settings to require strong passwords and MFA if supported

🧯 If You Can't Patch

  • Isolate server management interfaces on separate VLANs with strict access controls
  • Implement comprehensive logging and monitoring of all management interface access attempts

🔍 How to Verify

Check if Vulnerable:

Check firmware version in server management interface (BMC/IPMI) or via vendor-specific commands.

Check Version:

ipmitool mc info (Linux) or vendor-specific management software commands

Verify Fix Applied:

Confirm firmware version is 1.59 or later in server management interface.

📡 Detection & Monitoring

Log Indicators:

  • Unusual authentication attempts on server management interfaces
  • Firmware modification logs
  • Privilege escalation attempts in system logs

Network Indicators:

  • Unexpected connections to server management ports (623/664)
  • Traffic patterns indicating firmware manipulation

SIEM Query:

source="server-management" AND (event_type="authentication" OR event_type="firmware") AND result="failure"

🔗 References

📤 Share & Export