CVE-2020-29020

9.1 CRITICAL

📋 TL;DR

This vulnerability allows remote attackers to access the Secomea SiteManager web UI from the internet using configured credentials due to improper access control. It affects all SiteManager hardware versions prior to 9.4.620527004, potentially exposing management interfaces to unauthorized external access.

💻 Affected Systems

Products:
  • Secomea SiteManager
Versions: All versions prior to 9.4.620527004
Operating Systems: Embedded/Proprietary
Default Config Vulnerable: ⚠️ Yes
Notes: Only affects hardware versions; requires web service to be enabled and accessible.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete compromise of SiteManager devices allowing attackers to reconfigure industrial networks, disrupt operations, or pivot to internal systems.

🟠

Likely Case

Unauthorized access to management interface leading to configuration changes, data exposure, or denial of service.

🟢

If Mitigated

Limited impact if proper network segmentation and access controls prevent internet exposure.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires knowledge of valid credentials but access control bypass allows internet-based attacks.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: 9.4.620527004

Vendor Advisory: https://www.secomea.com/support/cybersecurity-advisory/#3217

Restart Required: Yes

Instructions:

1. Download firmware version 9.4.620527004 from Secomea support portal. 2. Backup current configuration. 3. Upload and install new firmware via web UI. 4. Reboot device. 5. Restore configuration if needed.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate SiteManager devices from internet access using firewalls or network segmentation.

Access Control Lists

all

Implement strict source IP restrictions to limit web UI access to trusted networks only.

🧯 If You Can't Patch

  • Implement network-level access controls to block all internet traffic to SiteManager web ports (typically 80/443).
  • Change all default credentials and implement strong password policies for all user accounts.

🔍 How to Verify

Check if Vulnerable:

Check firmware version in web UI under System > About. If version is below 9.4.620527004, device is vulnerable.

Check Version:

Not applicable - check via web UI or device console.

Verify Fix Applied:

Confirm firmware version shows 9.4.620527004 or higher in System > About page.

📡 Detection & Monitoring

Log Indicators:

  • Failed authentication attempts from external IPs
  • Successful logins from unexpected IP ranges
  • Configuration changes from unauthorized sources

Network Indicators:

  • External connections to SiteManager web ports (80/443)
  • Unusual traffic patterns to industrial control network

SIEM Query:

source_ip IN (external_ips) AND dest_port IN (80,443) AND dest_ip IN (sitemanager_ips)

🔗 References