CVE-2020-10042

9.8 CRITICAL

📋 TL;DR

A buffer overflow vulnerability in Siemens SICAM MMU, SGU, and T web applications allows attackers with network access to execute arbitrary code. This affects all versions of SICAM SGU and specific older versions of MMU and T devices. The vulnerability enables remote code execution with high impact.

💻 Affected Systems

Products:
  • SICAM MMU
  • SICAM SGU
  • SICAM T
Versions: SICAM MMU: All versions < V2.05, SICAM SGU: All versions, SICAM T: All versions < V2.18
Operating Systems: Embedded/Proprietary
Default Config Vulnerable: ⚠️ Yes
Notes: Affects web application components of these industrial control system devices.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise allowing attacker to execute arbitrary code, potentially gaining full control of affected devices, disrupting industrial operations, and pivoting to other network segments.

🟠

Likely Case

Remote code execution leading to device compromise, data theft, or disruption of industrial control system operations.

🟢

If Mitigated

Limited impact if devices are isolated in protected networks with strict access controls and monitoring.

🌐 Internet-Facing: HIGH
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Buffer overflow vulnerabilities typically have low exploitation complexity, especially when network-accessible.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: SICAM MMU: V2.05 or later, SICAM T: V2.18 or later, SICAM SGU: No fixed version available (consider mitigation strategies)

Vendor Advisory: https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf

Restart Required: Yes

Instructions:

1. Download updated firmware from Siemens support portal. 2. Backup device configuration. 3. Apply firmware update following Siemens documentation. 4. Verify update completion and restore configuration if needed.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate affected devices in protected network segments with strict firewall rules.

Access Control

all

Restrict network access to web interfaces using firewall rules and authentication.

🧯 If You Can't Patch

  • Implement strict network segmentation and firewall rules to limit access to affected devices
  • Deploy intrusion detection systems to monitor for exploitation attempts

🔍 How to Verify

Check if Vulnerable:

Check device firmware version via web interface or CLI and compare against affected versions.

Check Version:

Device-specific commands vary; typically accessible via web interface or serial console.

Verify Fix Applied:

Verify firmware version is updated to patched versions: MMU ≥ V2.05, T ≥ V2.18.

📡 Detection & Monitoring

Log Indicators:

  • Unusual web application access patterns
  • Buffer overflow error messages in device logs
  • Unexpected process execution

Network Indicators:

  • Unusual traffic to web application ports (typically 80/443)
  • Malformed HTTP requests to device web interfaces

SIEM Query:

source_ip="*" AND dest_port IN (80, 443) AND dest_ip="[device_ip]" AND http_request CONTAINS "buffer" OR "overflow"

🔗 References

📤 Share & Export