CVE-2019-9863

9.8 CRITICAL

📋 TL;DR

This vulnerability allows attackers to predict valid rolling codes used by ABUS Secvest wireless alarm systems, enabling unauthorized remote control of alarm systems. Affected users include anyone using ABUS Secvest FUAA50000 version 3.01.01 with FUBE50014 or FUBE50015 remote controls.

💻 Affected Systems

Products:
  • ABUS Secvest wireless alarm system FUAA50000
  • ABUS Secvest remote control FUBE50014
  • ABUS Secvest remote control FUBE50015
Versions: 3.01.01
Operating Systems: Embedded system firmware
Default Config Vulnerable: ⚠️ Yes
Notes: All systems using the default rolling code algorithm are vulnerable. The vulnerability is in the cryptographic implementation, not configuration-dependent.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Attackers can remotely disable alarm systems, disarm security zones, trigger false alarms, or prevent legitimate alarm activation, potentially enabling physical intrusion without detection.

🟠

Likely Case

Attackers can disarm alarm systems to facilitate burglaries or other unauthorized access to secured premises.

🟢

If Mitigated

With proper network segmentation and physical security controls, impact is limited to alarm system manipulation without broader network compromise.

🌐 Internet-Facing: LOW
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ⚠️ Yes
Weaponized: CONFIRMED
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Exploitation requires proximity to capture rolling codes (within wireless range), but no authentication or special privileges needed. Attack tools have been demonstrated publicly.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Contact ABUS for updated firmware

Vendor Advisory: https://www.abus.com/security-advisory

Restart Required: Yes

Instructions:

1. Contact ABUS support for firmware update. 2. Download updated firmware from ABUS portal. 3. Apply firmware update to alarm system via management interface. 4. Replace or update remote controls as directed by vendor.

🔧 Temporary Workarounds

Physical security enhancement

all

Implement additional physical security layers to compensate for vulnerable alarm system

Wireless signal monitoring

all

Deploy wireless intrusion detection to monitor for suspicious RF activity near alarm systems

🧯 If You Can't Patch

  • Replace vulnerable alarm system and remote controls with updated models
  • Implement secondary alarm systems using different technology (wired systems, different vendors)

🔍 How to Verify

Check if Vulnerable:

Check system firmware version in alarm system management interface. If version is 3.01.01, system is vulnerable.

Check Version:

Check via alarm system management interface (no CLI command available)

Verify Fix Applied:

Verify firmware version has been updated to a version later than 3.01.01 and test alarm functionality with updated remote controls.

📡 Detection & Monitoring

Log Indicators:

  • Multiple failed disarm attempts
  • Unusual disarm patterns
  • Alarm system state changes without authorized user activity

Network Indicators:

  • Unusual RF signal patterns in 868MHz band
  • Repeated rolling code transmissions from unknown sources

SIEM Query:

Not applicable - primarily physical/embedded system without network logging

🔗 References

📤 Share & Export