CVE-2018-11466

9.8 CRITICAL

📋 TL;DR

A critical vulnerability in Siemens SINUMERIK CNC systems allows remote attackers to send specially crafted packets to port 102/tcp, potentially causing denial-of-service or remote code execution in the software firewall. This affects multiple SINUMERIK product lines including 808D, 828D, and 840D sl systems. Attackers with network access to vulnerable systems can exploit this without authentication or user interaction.

💻 Affected Systems

Products:
  • SINUMERIK 808D
  • SINUMERIK 828D
  • SINUMERIK 840D sl
Versions: 808D V4.7 (all versions), 808D V4.8 (all versions), 828D V4.7 (all versions < V4.7 SP6 HF1), 840D sl V4.7 (all versions < V4.7 SP6 HF5), 840D sl V4.8 (all versions < V4.8 SP3)
Operating Systems: SINUMERIK-specific firmware
Default Config Vulnerable: ⚠️ Yes
Notes: Port 102/tcp (ISO-TSAP) is typically enabled by default for industrial communication protocols.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Remote code execution leading to complete system compromise, allowing attackers to manipulate CNC operations, steal sensitive industrial data, or cause physical damage to manufacturing equipment.

🟠

Likely Case

Denial-of-service condition disrupting manufacturing operations, potentially causing production downtime and financial losses.

🟢

If Mitigated

Limited impact if systems are properly segmented and access to port 102/tcp is restricted to trusted networks only.

🌐 Internet-Facing: HIGH - Systems exposed to the internet are extremely vulnerable as exploitation requires only network access to port 102/tcp.
🏢 Internal Only: HIGH - Even internally, attackers with network access can exploit this vulnerability without authentication.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

No public exploit code was known at advisory publication, but the vulnerability is unauthenticated and network-accessible, making exploitation relatively straightforward for skilled attackers.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: 808D: No patch available (consider upgrading), 828D: V4.7 SP6 HF1, 840D sl: V4.7 SP6 HF5 or V4.8 SP3

Vendor Advisory: https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf

Restart Required: Yes

Instructions:

1. Download appropriate firmware updates from Siemens support portal. 2. Backup current configuration. 3. Apply firmware update following Siemens documentation. 4. Restart affected systems. 5. Verify successful update.

🔧 Temporary Workarounds

Network Segmentation

all

Restrict access to port 102/tcp using firewall rules to only trusted networks and devices.

Disable Unnecessary Services

all

If ISO-TSAP service on port 102 is not required, disable it completely.

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate SINUMERIK systems from untrusted networks
  • Deploy intrusion detection systems to monitor for anomalous traffic on port 102/tcp

🔍 How to Verify

Check if Vulnerable:

Check SINUMERIK system version against affected versions list. Use network scanning tools to verify port 102/tcp is accessible.

Check Version:

Check version through SINUMERIK HMI interface or diagnostic tools specific to each product line.

Verify Fix Applied:

Verify system version is updated to patched versions: 828D V4.7 SP6 HF1 or higher, 840D sl V4.7 SP6 HF5 or higher, or V4.8 SP3 or higher.

📡 Detection & Monitoring

Log Indicators:

  • Unusual connection attempts to port 102/tcp
  • Firewall service crashes or restarts
  • Anomalous network traffic patterns

Network Indicators:

  • Malformed packets to port 102/tcp
  • Unexpected connections from untrusted sources to port 102

SIEM Query:

source_port:102 AND (packet_size:anomalous OR protocol_violation:true)

🔗 References

📤 Share & Export