CVE-2018-11462

9.8 CRITICAL

📋 TL;DR

This vulnerability allows remote attackers to escalate privileges to elevated user accounts (though not root) by sending specially crafted authentication requests to affected Siemens SINUMERIK CNC systems. It affects SINUMERIK 808D, 828D, and 840D sl systems with specific vulnerable firmware versions. Successful exploitation requires no user interaction or existing privileges.

💻 Affected Systems

Products:
  • SINUMERIK 808D
  • SINUMERIK 828D
  • SINUMERIK 840D sl
Versions: V4.7 (all versions for 808D, < V4.7 SP6 HF1 for 828D, < V4.7 SP6 HF5 for 840D sl), V4.8 (all versions for 808D, < V4.8 SP3 for 840D sl)
Operating Systems: SINUMERIK firmware
Default Config Vulnerable: ⚠️ Yes
Notes: All affected versions in default configuration are vulnerable. Requires network access to the CNC system.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete compromise of CNC system allowing unauthorized control of industrial equipment, potential production disruption, data theft, and manipulation of manufacturing processes.

🟠

Likely Case

Unauthorized access to CNC systems allowing configuration changes, program modifications, and potential production quality issues.

🟢

If Mitigated

Limited impact with proper network segmentation and access controls preventing external attackers from reaching vulnerable systems.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

No authentication required, exploit complexity appears low based on CVSS score and description. No public proof-of-concept known at advisory publication.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: SINUMERIK 828D V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 SP3

Vendor Advisory: https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf

Restart Required: Yes

Instructions:

1. Download appropriate firmware update from Siemens support portal. 2. Backup current configuration. 3. Apply firmware update following Siemens documentation. 4. Restart system. 5. Verify update applied successfully.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate SINUMERIK systems from untrusted networks using firewalls and VLANs

Access Control Lists

all

Restrict network access to SINUMERIK systems to only authorized IP addresses

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate vulnerable systems
  • Monitor network traffic for authentication anomalies and unauthorized access attempts

🔍 How to Verify

Check if Vulnerable:

Check SINUMERIK firmware version via HMI interface or diagnostic tools. Compare against vulnerable versions listed in advisory.

Check Version:

Check via SINUMERIK HMI: Menu → Diagnostics → Version

Verify Fix Applied:

Verify firmware version matches patched versions: 828D V4.7 SP6 HF1+, 840D sl V4.7 SP6 HF5+, or 840D sl V4.8 SP3+

📡 Detection & Monitoring

Log Indicators:

  • Multiple failed authentication attempts followed by successful authentication from same source
  • Authentication requests with unusual patterns or timing

Network Indicators:

  • Authentication traffic to SINUMERIK systems from unexpected sources
  • Traffic patterns matching known exploit signatures

SIEM Query:

source_ip=* AND destination_port=102 AND (authentication_failure OR authentication_success) AND protocol=S7comm

🔗 References